Outdoor Performance Assessment of New and Old Photovoltaic Panel Technologies Using a Designed Multi-Photovoltaic Panel Power Measurement System
International Journal Of Photoenergy, cilt.2020, ss.1-18, 2020 (SCI-Expanded, Scopus)
- Yayın Türü: Makale / Tam Makale
- Cilt numarası: 2020
- Basım Tarihi: 2020
- Doi Numarası: 10.1155/2020/8866412
- Dergi Adı: International Journal Of Photoenergy
- Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus, Academic Search Premier, Aerospace Database, CAB Abstracts, Communication Abstracts, INSPEC, Metadex, Veterinary Science Database, Directory of Open Access Journals, Civil Engineering Abstracts
- Sayfa Sayıları: ss.1-18
- Açık Arşiv Koleksiyonu: AVESİS Açık Erişim Koleksiyonu
- Ankara Yıldırım Beyazıt Üniversitesi Adresli: Hayır
Özet
This paper presents a new multi-photovoltaic panel measurement and analysis system (PPMAS) developed for measurement of
atmospheric parameters and generated power of photovoltaic (PV) panels. Designed system presented with an experimental
study evaluates performance of four new and four 5-year-old PV panel technologies which are based on polycrystalline (Poly),
monocrystalline (Mono), copper indium selenide (CIS), and cadmium telluride (CdTe) in real time, under same atmospheric
conditions. The PPMAS system with the PV panels is installed in Yildirim Beyazit University, Ankara Province, in Turkey. The
designed PPMAS consists of three different subsystems which are (1) photovoltaic panel measurement subsystem (PPMS), (2)
meteorology measurement subsystem (MMS), and (3) data acquisition subsystem (DAS). PPMS is used to measure the power
generation for PV panels. MMS involves different types of sensors, and it is designed to determine atmospheric conditions
including wind speed, wind direction, outdoor temperature, humidity, ambient light, and panel temperatures. The measured
values by PPMS and MMS are stored in a database using DAS subsystem. In order to improve the measurement accuracy,
PPMS and MMS are calibrated. This study also focuses on outdoor testing performances of four new and four 5-year-old PV
panels. Average monthly panel efficiencies are estimated as 8.46%, 8.11%, 5.65%, and 3.88% for new Mono, new Poly, new CIS,
and new CdTe PV panels, respectively. Moreover, average monthly panel efficiencies of old panels are calculated as 8.22%,
7.85%, 5.35%, and 3.63% in the same order. Test results obtained from the experimental system are also statistically examined
and discussed to analyze the performance of PV panels in terms of monthly panel efficiencies.