Effect of straight and angled abutments on the strain on a zirconia crown and implant in the mandibular second molar region: A fea-based study


Creative Commons License

Özdoğan M. S., Gokce H., Şahin İ.

Materiali in Tehnologije, cilt.54, ss.251-257, 2020 (SCI-Expanded, Scopus)

  • Yayın Türü: Makale / Tam Makale
  • Cilt numarası: 54
  • Basım Tarihi: 2020
  • Doi Numarası: 10.17222/mit.2019.121
  • Dergi Adı: Materiali in Tehnologije
  • Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus, Directory of Open Access Journals
  • Sayfa Sayıları: ss.251-257
  • Açık Arşiv Koleksiyonu: AVESİS Açık Erişim Koleksiyonu
  • Ankara Yıldırım Beyazıt Üniversitesi Adresli: Hayır

Özet

© 2020 Institute of Metals Technology.In a literature search no study evaluating implant-supported posterior restorations using zircon crowns with straight and angled abutments was found. In this study, the stress distribution of a zircon-crown restoration that will be prepared by using an angular and straight abutment in a mandibular second-molar deficiency, under functional forces, stress over zircon crown and environmental tissues of implant will be evaluated using the finite-element analysis (FEA) method. The FEA result showed that the use of straight implants contributes to the lowest stresses. The selection of a straight and angular abutment is very important for the balance of distributed loading.