Effect of straight and angled abutments on the strain on a zirconia crown and implant in the mandibular second molar region: A fea-based study


Özdoğan M. S. , Gokce H., Şahin İ.

Materiali in Tehnologije, cilt.54, ss.251-257, 2020 (SCI Expanded İndekslerine Giren Dergi) identifier

  • Cilt numarası: 54
  • Basım Tarihi: 2020
  • Doi Numarası: 10.17222/mit.2019.121
  • Dergi Adı: Materiali in Tehnologije
  • Sayfa Sayıları: ss.251-257

Özet

© 2020 Institute of Metals Technology.In a literature search no study evaluating implant-supported posterior restorations using zircon crowns with straight and angled abutments was found. In this study, the stress distribution of a zircon-crown restoration that will be prepared by using an angular and straight abutment in a mandibular second-molar deficiency, under functional forces, stress over zircon crown and environmental tissues of implant will be evaluated using the finite-element analysis (FEA) method. The FEA result showed that the use of straight implants contributes to the lowest stresses. The selection of a straight and angular abutment is very important for the balance of distributed loading.