Evaluation of Intraocular Pressure by Ocular Response Analyzer in Patients Undergoing Hemodialysis
JOURNAL OF GLAUCOMA, cilt.25, sa.4, 2016 (SCI-Expanded, Scopus)
- Yayın Türü: Makale / Tam Makale
- Cilt numarası: 25 Sayı: 4
- Basım Tarihi: 2016
- Doi Numarası: 10.1097/ijg.0000000000000364
- Dergi Adı: JOURNAL OF GLAUCOMA
- Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus
- Ankara Yıldırım Beyazıt Üniversitesi Adresli: Evet
Özet
Purpose: The aim of this study was to compare the biomechanical parameters of the cornea and intraocular pressure (IOP) before and after hemodialysis (HD) in patients with end-stage renal disease (ESRD) and also healthy subjects.