Diagnostic value of tear Galectin-1 and Galectin-3 in keratoconus: a prospective case-control study


Kosekahya A., KÖSEKAHYA P., Turk H. B., Avcioglu G., EREL Ö., ERDEM A.

BMC Ophthalmology, cilt.26, sa.1, 2026 (SCI-Expanded, Scopus)

  • Yayın Türü: Makale / Tam Makale
  • Cilt numarası: 26 Sayı: 1
  • Basım Tarihi: 2026
  • Doi Numarası: 10.1186/s12886-026-05192-y
  • Dergi Adı: BMC Ophthalmology
  • Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus, CINAHL, EMBASE, MEDLINE, Directory of Open Access Journals, Biomedical Reference Collection: Corporate Edition (EBSCO), Health Research Premium Collection (ProQuest)
  • Anahtar Kelimeler: Corneal tomography, Galectin-1, Galectin-3, Keratoconus, Tear film
  • Ankara Yıldırım Beyazıt Üniversitesi Adresli: Hayır

Özet

Background: This study aims to evaluate tear Galectin-1 and Galectin-3 levels in patients with keratoconus and healthy controls, assess their diagnostic performance, and investigate their associations with corneal tomography parameters. Methods: This prospective case–control study included 40 eyes of 40 patients with keratoconus and 33 eyes of 33 healthy controls. All participants underwent a comprehensive ophthalmic examination and corneal tomographic assessment using a Scheimpflug imaging system. Tear samples were collected using Schirmer strips, and Galectin-1 and Galectin-3 concentrations were measured using enzyme-linked immunosorbent assay (ELISA). Receiver operating characteristic (ROC) curve analysis was performed to assess the diagnostic performance of Galectin-1 and Galectin-3 to discriminate between keratoconus and healthy controls, and correlation analyses were performed to explore the relationships between galectin levels and corneal tomographic parameters. Results: The keratoconus and control groups were comparable in terms of age, sex distribution, and tear sample volume (all p > 0.05). Tear Galectin-1 and Galectin-3 levels were significantly higher in the keratoconus group than in controls (1033 ± 570 vs. 617 ± 172 pg/mL, p = 0.006; and 16.4 ± 5.4 vs. 7.1 ± 4.7 ng/mL, p < 0.001, respectively). ROC analysis demonstrated AUC values of 0.687 for Galectin-1 and 0.899 for Galectin-3. At a cut-off value of 10.93 ng/mL, Galectin-3 showed a sensitivity of 87.5% and a specificity of 78.8% for discriminating keratoconus from healthy controls. When correlation analyses were performed exclusively within the keratoconus group, no significant correlations were observed between galectin levels and corneal tomographic parameters. Conclusion: Tear Galectin-1 and Galectin-3 levels were significantly elevated in patients with keratoconus compared with healthy controls. Among the two galectins, Galectin-3 demonstrated superior diagnostic performance, supporting further investigation of Galectin-3 as a potential biomarker for keratoconus.