Passive mitigation of buoyant thermal plumes in turbine casings during shutdown to support operational flexibility


MURAT O., Rosic B.

Applied Thermal Engineering, cilt.309, 2026 (SCI-Expanded, Scopus)

  • Yayın Türü: Makale / Tam Makale
  • Cilt numarası: 309
  • Basım Tarihi: 2026
  • Doi Numarası: 10.1016/j.applthermaleng.2026.133932
  • Dergi Adı: Applied Thermal Engineering
  • Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus, Compendex, INSPEC, DIALNET, Business Source Ultimate (EBSCO)
  • Anahtar Kelimeler: Mixed convection, Operational flexibility, Passive flow control, Thermal plume, Turbine flexibility, Turbine shutdown
  • Ankara Yıldırım Beyazıt Üniversitesi Adresli: Evet

Özet

Mixed convection in turbine casing cavities during shutdown produces buoyant thermal plumes and circumferentially non-uniform cooling, which contribute to casing distortion and constrain operational flexibility. This study examines whether such plumes can be suppressed passively, without increasing the cavity through-flow. Four geometric concepts were screened with steady Reynolds-averaged Navier–Stokes (RANS) simulations in a horizontal annulus with a heated inner cylinder and axial cross-flow at a Richardson number of 0.472. The most promising, an upstream plate blocking half of the annular gap, was investigated experimentally and with wall-resolved large-eddy simulation (LES). At the same mass flow rate, the plate reduced the measured circumferential standard deviation of the non-dimensional fluid temperature by 83%–85% at the downstream sections (73%–78% when evaluated over the full circumference in the LES). The LES attributes this to redistribution of the existing axial momentum, which reduces the magnitude of the mean vertical motion in the upper annulus by 19%–35% and suppresses the buoyancy-induced helical structures; it also predicts that the circumferential variation of the Nusselt number, relative to its mean, falls by 52%–74%. The plate raises the total-pressure loss coefficient by about 7.5, consistent with thin-orifice theory, whereas an unobstructed high-flow reference case suppresses the plume by increasing the mass flow 3.95-fold. Passive momentum redistribution therefore offers a potential route to mitigating shutdown thermal asymmetry when the available cavity flow is limited, although its effectiveness along a full shutdown trajectory remains to be demonstrated.