Occlusal Thickness and Cement-Type Effects on Fracture Resistance of Implant-Supported Posterior Monolithic Zirconia Crowns


Bulut A. C., Atsü S. S.

International Journal of Oral and Maxillofacial Implants, cilt.36, sa.3, ss.485-491, 2021 (SCI-Expanded, Scopus)

  • Yayın Türü: Makale / Tam Makale
  • Cilt numarası: 36 Sayı: 3
  • Basım Tarihi: 2021
  • Doi Numarası: 10.11607/jomi.8503
  • Dergi Adı: International Journal of Oral and Maxillofacial Implants
  • Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus, CINAHL, EMBASE, MEDLINE, DIALNET
  • Sayfa Sayıları: ss.485-491
  • Anahtar Kelimeler: CAD/CAM, cement, fracture resistance, implant-supported crown, monolithic zirconia crown, occlusal thickness
  • Ankara Yıldırım Beyazıt Üniversitesi Adresli: Hayır

Özet

Purpose:To evaluate the factors that could influence the fracture resistance of implant-supported posterior monolithic zirconia crowns. Materials and Methods: Sixty zirconia molar crowns with three different occlusal thicknesses of 0.5, 1.0, and 1.5 mm (20 samples per group) were prepared for implant abutments using a CAD/CAM system. In each group, 10 crowns were luted on the abutment with resin cement (Panavia F), and the other 10 crowns were luted with resin-modified glass-ionomer cement (Ketac Cem Plus). Dynamic loading (1.2 × 106 cycles; 70 N) and thermal cycling were applied to the samples using a chewing simulator before evaluating their fracture resistance with a universal testing machine and examining their fracture type using a stereomicroscope. One-way analysis of variance (ANOVA), the Duncan test, and two-way ANOVA were used for data evaluation (a = .05). Results: The occlusal thickness (P < .001) and cement type (P < .01) affected the fracture load of the monolithic zirconia crowns. The highest fracture resistance was found in 1.5-mm-thick crowns luted with resin cement (4,212 ± 501 N), and the lowest fracture resistance was found in 0.5-mm and 1-mm-thick crowns luted with resin-modified glass-ionomer cement (1,198 ± 116 N and 1,197 ± 66 N). A significant difference was not found in the mean maximum fracture load between the 1.5-mm-thick crowns cemented with resin cement and glass-ionomer resin cement. Conclusion: Both the occlusal thickness and cement type remarkably affected the fracture resistance of the crowns, but occlusal thickness was more significant. Implant-supported posterior zirconia crowns can withstand physiologic occlusal forces even with a thickness as low as 0.5 mm. Resin luting cement is recommended for implant-supported posterior zirconia crowns with reduced occlusal thickness.